Get Up to 80% OFF on our Discontinued and Overstock Items. Call for details.* Limited quantities.
Reed 8906 Vane Thermo-Anemometer with Air Volume

Reed 8906 Vane Thermo-Anemometer with Air Volume

Reed R9910SD Data Logging Air Quality Meter

$1,490.00

Reed R9910SD Data Logging Air Quality Meter

Real-time data logger with integrated SD memory card measures/records oxygen, carbon dioxide, carbon monoxide, temperature and humidity

The R9910SD is capable of recording readings from 3 probes simultaneously and features Data hold, Max/Min functions, and an easy-to-read backlit LCD display. Using a SD card (max 16GB), a user can manually record up to 99 readings or automatically by selecting a desired sampling rate from 1 sec to 8 hours. Quickly generate an Excel file with raw data, all without the use of software. Optional accessories include a tripod and AC adapter for continuous long-term monitoring.

  • Measures oxygen (O2), carbon dioxide (CO2), carbon monoxide (CO), temperature and humidity
  • Records up to 3 readings simultaneously
  • User adjustable audible alarms
  • User selectable unit of measure (°C or °F)
  • Data hold and Max/Min functions
  • Real-time data logger with integrated SD memory card
  • User selectable sampling rate from 2 secs to 8 hrs
  • Easy-to-read backlit LCD display
  • Tripod mount for long-term monitoring
  • Low battery indicator and auto shut off

REED R9910SD Specifications

Temperature
Measuring Ranges 32 to 122.0°F (0 to 50.0°C)
Dew Point: -13.5 to 120.1°F (-25.3 to 48.9°C)
Wet Bulb: -6.9 to 122.0°F (-21.6 to 50°C)
Accuracy ±1.5°F (±0.8°C)
Resolution 0.1°F/°C
Humidity
Measuring Ranges 5 to 95%RH
Accuracy >70%RH: ±(3% rdg + 1%RH)
<70%RH: ±3%RH
Resolution 0.1%RH
CO2
Measuring Ranges 0 to 4,000 ppm
Accuracy <999 ppm: ±40 ppm
>1,000 ppm ≤3000 ppm: ±5% rdg
>3,000 ppm: ±250 ppm
Resolution 1 ppm
CO
Measuring Ranges 0 to 1,000 ppm
Accuracy ±(5% + 2 ppm)
Resolution 1 ppm
O2
Measuring Ranges 0 to 30% O2
Accuracy ±(1% + 0.2% O2)
Resolution 0.10%
General Specifications
Alarm Threshold <18% O2
Response Time 1 second
Display 4-digit dual LCD
Backlit Display Yes
Data Hold Yes
Min Yes
Max Yes
Datalogging Capabilities Yes
Real-Time Clock and Date Stamp Yes
Selectable Sampling Rate Yes (1 second to 8 hours, 59 minutes and 59 seconds)
External Memory Yes, expandable up to 16GB with SD card (optional)
Auto Shut-off Yes (after 10 minutes/off)
Kick Stand Yes
Tripod Mountable Yes
Low Battery Indicator Yes
Power Supply 6 x AA Batteries or AC Adapter (optional)
Data Output Yes (RS-232)
Product Certifications CE
Operating Temperature 32 to 122°F (0 to 50°C)
Storage Temperature 14 to 140°F (-10 to 60°C)
Operating Humidity Range 10 to 85%
Dimensions Instrument: 7.0 x 2.7 x 1.8" (177 x 68 x 45mm)
Humidity Probe Length: 7.8" (197mm)
CO Probe Length: 5.9" (150mm)
CO2 Probe Length: 7.5" (190mm)
O2 Probe Length: 5.9" (150mm)
Weight 0.8lb (350g)
SKU
R9910SD
More Information
Manufacturer Reed Instruments
Unit of Measure Each
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Customer Questions
No Questions